Study objective and approach
Internal voids can alter a component's dynamic response. Laser Acoustic Resonance Spectroscopy (LARS) compares measured resonance signatures against reference measurements and assigns a similarity score. A score below the selected threshold flags a bracket for rejection or further review. This case study investigates how designed void fraction, defect location, build orientation, and analyzed spectral bandwidth influence detection performance, reference repeatability, and the tradeoff between defect detection and pristine acceptance.
Measured specimens and test conditions
| Population | Count | Role | Notes |
|---|---|---|---|
| Reference brackets | 3 | Reference construction | L1, L3, L4; not specificity controls |
| Repeat measurements | 8 | Repeatability / expanded acceptance | 3 × L1; 3 × L3; 2 × L4 |
| Independent pristine | 1 | Independent acceptance control | Y7 |
| Defective brackets | 36 | Observed detection fraction | Large (M), medium (N), small (O), corner (P-V), side-Z (W-X) |
| Build-orientation specimens | 4 | Separate sensitivity study | Y1–Y4; excluded from confusion matrices |
Bracket geometry & designed void locations
Bracket geometry and defect locations
Specimen identification
| Specimen | Defect / configuration | Void fraction (%) [from CAD] |
|---|
Reference and build-orientation specimens are identified separately from intentionally defective brackets.
Explore the results
All five plots, key metrics, and confusion matrices respond to the same analysis controls.
Five-plot evidence story
Designed void fraction and observed defect detection
Nominal void fraction (%) is a designed-geometry proxy, not CT-measured porosity.
Threshold and frequency must be chosen together
Detection probability and pristine acceptance move together as the rejection threshold changes.
Reference measurement repeatability
Reference and repeat measurements across three spectral windows.The dashed threshold line defines the minimum similarity required for acceptance. Repeat measurements below this line are flagged for rejection.
Does a wider band help at low void fractions?
Paired specimen comparisons, with no assumption that individual modal mechanisms have been isolated.
Build-orientation sensitivity
Y1–Y4 are analyzed separately from defect POD and pristine specificity.
Decision summary
The table, selected operating point, and confusion matrix update when the controls change.
Key threshold results: 0.90, 0.95, 0.98
| Threshold | Frequency | Detected defects | Missed defects | Controls accepted | Controls rejected |
|---|
Confusion matrix at the selected operating point
Rows = actual condition; columns = LARS decision. The threshold rejects a bracket when its similarity score is strictly below T.
How to interpret these results
True positive (TP): a defective bracket correctly rejected. False negative (FN): a defective bracket incorrectly accepted. True negative (TN): a pristine control correctly accepted. False positive (FP): a pristine control incorrectly rejected.
POD = TP / (TP + FN); observed control acceptance = TN / (TN + FP). With only Y7 as an independent pristine control, statistical specificity for new production parts remains unestablished.